A technical guide to selecting visual, audible and combined signaling devices for industrial machinery.
A machine status indicator forms part of the interface between a machine and the people who operate or maintain it. It may confirm normal operation, request action or communicate a fault or hazardous condition. Selection must begin with the required information and human response, not with colour, sound level or housing shape.
Status indication, warning and alarm are different functions. A green operating light, an amber maintenance request and a start-up warning require different levels of perceptibility and different operating modes. The complete application must therefore be assessed: machine states, human response, viewing and hearing distance, ambient conditions, mounting, electrical integration, maintenance and applicable standards.
Selection principle: define the signaling task and required response first. Then verify that the selected device is perceptible throughout the required area and compatible with the machine environment and control system.
Define the required signaling function

Before comparing products, list the machine states that must be communicated and assign an expected response to each one. Typical examples include:
-Machine ready or automatic cycle active
-Material supply low
-Operator action or maintenance required
-Process outside its normal range
-Machine fault or production stop
-Hazardous start-up or movement imminent
-Emergency condition requiring immediate action
This prevents colours and flashing patterns from being added without a defined meaning. Each state should have a distinct purpose that remains consistent across the machine, HMI and production area.
Also identify who must receive the signal. A local operator indicator has a different required range from one intended for personnel across a production hall. If people may not be looking at the machine, visual indication alone may be insufficient.
Distinguish indication, warning and alarm
Pfannenberg separates signaling tasks into indication, warning and alarm. This distinction helps determine the required level of attention and the appropriate device type.
| Purpose | Typical meaning | Expected response | Possible device type |
|---|---|---|---|
| Indication | Routine operating or process information | Awareness or normal action | Steady light, status bar, dome light or signal tower |
| Warning | Abnormal condition or potential hazard | Monitor or take corrective action | Blinking or flashing light, sounder or combined device |
| Alarm | Dangerous or emergency condition | Immediate action | High-perceptibility device selected for the applicable requirements |
The machine risk assessment must define the boundaries. A standard status light is not a safety function merely because it displays red or flashes. If risk reduction depends on signaling, the required performance level, architecture, diagnostics and certification must be established separately.
Reserve the most attention-demanding modes for the highest-priority events. If routine states use loud tones or flashing lights, personnel may find it harder to recognise a condition that requires immediate action.
Choose visual, audible or combined signaling
Visual signaling devices
Visual indicators suit routine information when personnel can see the machine. Formats include dome lights, status bars, beacons and signal towers. A tower separates several states by colour or module position, while an RGB device can represent multiple states from one compact surface.
Visual signaling alone may be unsuitable where operators face away from the machine, structures obstruct the indicator or ambient light reduces contrast. Colour should be supported by position, text, an HMI message or a distinct operating pattern where misinterpretation could have consequences.
Audible signaling devices
An audible device attracts attention independently of viewing direction. It may warn personnel before a machine starts, call an operator to a remote machine or communicate a condition across a work area.
Nominal sound pressure level is only one selection parameter. Ambient-noise frequencies, walls, enclosures and hearing protection can impair perception. The tone must be distinguishable from local machinery and from other signals in the same area. The signaling concept should define when the sound begins, how long it continues, whether it can be acknowledged and which action it requires.
Combined visual and audible devices
A combined device is appropriate where visibility or audibility varies. Both elements should use coordinated meanings and logic. For example, an acknowledged sound may stop while the visual indication remains active until the condition is cleared.
Determine the required visual coverage

Define every position from which personnel must recognise the indication. Assess viewing distance and angle, mounting height, ambient light, reflections and obstructions.
Light output alone does not describe usable range. Distribution, lens colour, operating mode and viewing angle also affect perceptibility. Pfannenberg’s 3D-Coverage method evaluates performance as a three-dimensional signaling volume under defined conditions.
Large machines, multiple workstations or obstructed sight lines may require more than one device. Determine the number and positions from the required coverage, not only from the machine footprint.
Assess acoustic perceptibility
For a sounder, determine whether the intended receiver can distinguish the tone throughout the required area under realistic conditions.
Assess ambient noise at representative positions and during loud operating states. Include intermittent sources such as presses, extraction systems, conveyors and mobile equipment. Pfannenberg’s ISO 7731 guidance cites 15 dB above ambient noise throughout the reception area as one selection route for auditory danger signals, with octave-band or one-third-octave-band analysis as an alternative. Frequency content, barriers and hearing protection must also be considered.
These criteria concern auditory danger signals, not every routine machine sound. Where background noise is complex, compare the sounder spectrum with the dominant ambient frequencies.
Select light technology, modes and colours
LED and xenon devices have different performance characteristics. Neither is universally better. LED devices are commonly suited to continuous indication, blinking operation and configurable multi-colour signaling. Xenon devices produce a short, high-intensity flash with broad distribution, which can be useful where a strong alerting effect is required over a larger space.
Use a steady light for routine status information, blinking for a condition requiring increased attention and flashing where high perceptibility is required. An RGB device offers flexibility, but only approved colours and patterns should be available during normal machine operation.
Define every colour and signaling mode in the machine specification. Consider applicable standards, customer requirements and site conventions. The same state should not have different meanings on adjacent machines without a documented reason. Colour alone should not carry critical information where ambiguity is reasonably foreseeable.
Match the device to the environment and mounting position
Check the required IP rating, operating temperature, indoor or outdoor exposure, UV radiation, chemicals, cleaning processes, vibration, shock, corrosion and mechanical impact. The IP rating only covers defined ingress conditions. It does not automatically confirm chemical resistance, UV stability or suitability for high-pressure cleaning.
For explosive atmospheres, select an appropriately certified Ex or ATEX device for the classified zone and substance group. A robust industrial housing without the required certification is not an alternative.
The mounting position must provide the required visual or acoustic coverage while remaining accessible for wiring, testing and replacement. Confirm the permitted orientation and whether direct, bracket, pole, tube, panel or surface mounting is required. Record the position and orientation in the machine documentation so the arrangement can be reproduced across variants.
Verify the connection and control method
Electrical integration includes supply voltage, current consumption, switching method, output capacity, connector pin assignment and cable requirements.
A conventionally controlled indicator uses discrete PLC outputs or relays. This is often proportionate for a small number of fixed states. A multi-function device may require several outputs, depending on its input design.
An M12 connector can simplify field connection and replacement, but M12 describes the connector format. It does not determine whether the device uses discrete control or IO-Link. Always verify the product number and pin assignment.
An IO-Link device communicates with an IO-Link master port. Depending on the product, it can support central parameterisation, configurable colours or modes, identification data, events and parameter recovery. Verify master-port availability, port class, current, power budget, process-data mapping, IODD and the functions actually supported by the device.
IO-Link provides the most value when configurations are reused across machine variants, device data is used in maintenance or parameter recovery reduces replacement errors. Conventional control may be more efficient for a fixed function on a machine without IO-Link infrastructure.
Review standards and safety requirements

Pfannenberg identifies EN 60204-1 for machine electrical equipment, EN 61310-1 for visual, acoustic and tactile signals, and EN ISO 12100 for risk assessment and risk reduction as relevant European references. ISO 7731 addresses auditory danger signals for public and work areas.
Requirements depend on the machine, industry, market and signaling function. Verify the current edition and national adoption. Fire-alarm standards such as EN 54-3 and EN 54-23 do not automatically apply to ordinary machine status indicators.
If signaling contributes to a safety function, determine the required PL or SIL and use suitable certified components, diagnostics and architecture. A signal complements the hierarchy of risk-reduction measures. It does not replace guards, interlocks or other required protective measures.
Machine status indicator selection matrix
| Application requirement | Preferred starting point | Verify |
|---|---|---|
| One or two fixed states at a local position | Conventional visual indicator | Colour meaning, viewing position, supply and mounting |
| Several states visible from different directions | Signal tower or multi-colour device | Module meanings, angles, obstructions and range |
| Personnel may not be looking at the machine | Audible or combined device | Noise, tone, coverage and acknowledgement logic |
| Important warning under variable conditions | Combined visual and audible device | Coordination of both signals and required response |
| Reusable settings or diagnostics across variants | IO-Link device | Master, IODD, supported data and maintenance integration |
| Dust, water, vibration or outdoor exposure | Device with verified environmental ratings | IP plus temperature, UV, chemical and mechanical resistance |
| Hazardous area | Certified Ex or ATEX device | Zone, substance group and installation requirements |
| Defined safety-related signaling function | Certified device and suitable architecture | PL or SIL, diagnostics, validation and standards |
The matrix is a starting point. Check the final choice against the complete signaling concept and product documentation.
Engineering checklist before ordering
-Which states must be communicated, and what response does each require?
-Who must perceive the signal, and from which positions?
-Is the function indication, warning or alarm?
-Is visual, audible or combined signaling appropriate?
-Which distance, obstructions, lighting and noise affect perception?
-Which colours, tones and operating modes are approved?
-Which environmental and mechanical ratings are required?
-How will the device be mounted, connected, tested and replaced?
-Is conventional control sufficient, or does IO-Link provide defined value?
-Does the signaling function have safety-related requirements, and which standards and customer specifications apply?
Select against the complete application
Choosing a machine status indicator is an engineering task, not a decision based only on shape, colour or nominal output. Define the information and required response, select visual, audible or combined signaling, and verify performance throughout the actual reception area.
The solution must also suit the environment, mounting position, electrical system and maintenance strategy. Conventional products remain appropriate for stable functions. IO-Link is relevant where parameterisation, reusable configurations or device data create measurable value. Demanding environments and safety-related applications require the corresponding certification and system design.
Machine Safety Shop can supply the complete range of Pfannenberg visual and acoustic signaling devices. This allows the product type to be selected from the application requirements rather than from a restricted subset of devices.
Technical support for signaling-device selection
Machine Safety Shop can help assess the signaling task, coverage, ambient conditions, mounting, electrical connection and control method. Provide the machine layout, operating environment, required states and available control architecture for a focused technical selection.
Primary CTA: View Pfannenberg signaling devices
Secondary CTA: Request technical advice for your application
Editorial sources
Pfannenberg, status indication
Pfannenberg, signaling for recycling machines
Pfannenberg, ISO 7731 and audible danger signals
Pfannenberg, planning and dimensioning
Pfannenberg, signaling technology knowledge centre
Pfannenberg, 3D-Coverage
Pfannenberg, indication, warning and alarm
Pfannenberg, LED or xenon
Frequently asked questions
What type of machine status indicator should I use?
Use a visual indicator for routine information when personnel can see the machine, an audible device when attention must be attracted independently of viewing direction, and a combined device when important information must remain perceptible under varying conditions.
When should a signal tower be used instead of a single light?
A signal tower is useful when several defined states must be distinguished by colour or module position. A single or RGB light may suit a compact installation or an application in which only one active state needs to be shown.
How loud should an industrial sounder be?
The required level depends on ambient noise throughout the reception area. For auditory danger signals, assess sound level and frequency content, as well as hearing protection, barriers and intermittent machine noise.
Is LED or xenon better?
Neither is universally better. LED suits many continuous, blinking and configurable applications. Xenon provides short, high-intensity flashes. Select from the required coverage, duty cycle and environment.
Which IP rating is required?
Choose the IP rating from exposure to dust and water. Verify temperature, chemicals, UV, vibration, impact and cleaning separately because the IP rating does not define these properties.
Does an M12 connector mean the device uses IO-Link?
No. M12 identifies the connector format. An M12 device may use discrete control or IO-Link. Check the product number, pin assignment and technical documentation.
What does IO-Link add?
Depending on the device, IO-Link can support central parameterisation, configurable modes, identification data, events and parameter recovery. These functions provide value only when the control and maintenance systems use them.
Is a machine status indicator a safety device?
Not automatically. If risk reduction depends on successful signaling, define and validate the required PL or SIL, product certification, diagnostics and complete system architecture.
How many signaling devices does a machine need?
The number depends on the required coverage, mounting positions, obstructions, ambient conditions and personnel locations. Define the reception area first, then position devices so the signal is perceptible throughout it.