Signal Lights

Industrial signal lights, including LED signal towers, strobe lights and warning indicators, display machine status and faults on production lines, conveyors and automated machinery.

60
Signal Lights
  • 16 cd LED Light
  • 105 dB Sound Intensity
  • IO-Link variant

€217,00

(€262,57 incl. VAT)
  • Multifunctional LED lighting
  • 360° visibility
  • Optional IO-Link version

€152,60

(€184,65 – 432,70 incl. VAT)
Select options This product has multiple variants. The options may be chosen on the product page
  • 12-48 V DC
  • 3 LED lights
  • Without sounder

€412,00

(€498,52 incl. VAT)
  • 115/230 V AC; 120 V DC
  • 3 LED lamps
  • Without sounder

€412,00

(€498,52 incl. VAT)
  • 12-48 V DC
  • 2 LED lamps
  • Without sounder

€302,00

(€365,42 incl. VAT)
  • 115/230 V AC; 120 V DC
  • 2 LED lights
  • Without sounder

€302,00

(€365,42 incl. VAT)
  • 116 dB(A)
  • 80 different selectable tones
  • 12-48 V DC

€666,00

(€805,86 incl. VAT)
  • 116 dB(A)
  • 80 different selectable tones
  • 115 V AC

€703,00

(€850,63 incl. VAT)
  • 116 dB(A)
  • 80 different selectable tones
  • 230 V AC

€703,00

(€850,63 incl. VAT)
  • 116 dB(A)
  • 80 different selectable tones
  • 12-48 V DC

€666,00

(€805,86 incl. VAT)
  • 116 dB(A)
  • 80 different selectable tones
  • 115 V AC

€703,00

(€850,63 incl. VAT)
  • 116 dB(A)
  • 80 different selectable tones
  • 230 V AC

€703,00

(€850,63 incl. VAT)

Industrial Signal Lights and LED Warning Lights for Machine Safety

Industrial signal lights and LED warning lights provide visual indication of machine operating conditions, faults and potential hazards. They help operators and maintenance personnel monitor machine status, recognise abnormal conditions and respond to warnings.

Available as LED signal towers, strobe lights, panel-mount indicators, surface-mount warning lights and multifunction signalling devices, industrial signal lights are used on production lines, conveyor systems, packaging machines, robotic cells and automated manufacturing equipment.

 

What is an industrial signal light?

An industrial signal light is a visual signalling device used to communicate machine status, operating conditions, faults or warnings. Depending on its design, it uses coloured LED illumination, continuous light, flashing patterns or strobe signals to convey information.

Industrial signal lights are installed on machinery, control panels, production lines and automated systems to provide operators with visible information about equipment conditions.

They support operational monitoring and machine safety awareness but do not independently perform protective safety functions.

 

Why are industrial signal lights important for machine safety?

Industrial signal lights help operators identify machine conditions and recognise situations requiring attention. They can indicate whether equipment is running, stopped, experiencing a fault or awaiting operator intervention.

In machine safety applications, signal lights may display information from safety switches, guard locking devices, safety controllers and other monitoring equipment. For example, a warning light can indicate that a machine guard is open, an emergency-stop function has been activated or a fault requires investigation.

This information helps personnel understand machine conditions without relying exclusively on a local control panel.

Industrial signal lights provide visual indication and do not replace safety interlocks, emergency-stop functions, protective devices or other required safety measures.

 

How do industrial signal lights work?

Industrial LED signal lights receive electrical control signals from a PLC, safety controller, relay, sensor or machine control circuit. Depending on the device configuration, they activate a specific colour, illumination mode or warning pattern.

Common signalling modes include:

  • Continuous light: Provides steady indication of machine status or operating conditions.
  • Flashing light: Draws attention to warnings, faults or conditions requiring operator action.
  • Strobe light: Produces short, high-intensity flashes for conspicuous visual warnings.
  • Multicolour indication: Uses selectable LED colours to communicate different machine conditions within one device.
  • Combined audible and visual signalling: Integrates a warning light with a buzzer or sounder to provide both optical and acoustic alerts.

The selected signalling mode should match the intended message, operating environment and machine risk assessment.

 

Industrial signal light colours and their meaning

Industrial signal lights use colour coding to distinguish different machine conditions and support consistent interpretation by operators.

Colour Typical indication
Red Emergency, danger or hazardous condition requiring immediate attention
Yellow / amber Abnormal condition, warning or condition requiring monitoring
Green Normal condition or indication that a defined condition is satisfactory
Blue Condition requiring a specific operator action
White Neutral indication or general operating information

The meaning of each signal colour should be clearly defined for the machinery or installation and remain consistent across the equipment.

For example, a green signal must not be treated as independent confirmation that machinery is safe to access. Safe access depends on the appropriate protective measures and control system conditions.

 

Types of industrial signal lights and warning lights

Industrial signalling devices are available in different configurations to suit machine design, installation requirements and visibility needs.

 

LED signal towers

LED signal towers, also known as stack lights or tower lights, combine multiple illuminated segments within a vertical housing. Each segment can display a different colour to indicate machine status, warnings or faults.

These industrial status indicators are commonly installed on automated production lines, packaging machines, conveyor systems and robotic manufacturing equipment where operating conditions must be visible from a distance.

 

Industrial strobe lights

Industrial strobe lights produce short, high-intensity flashes to attract attention to warnings or abnormal operating conditions.

They are used on industrial machinery and automated equipment where a conspicuous visual warning is required. Selection should consider viewing distance, ambient lighting, flash characteristics and personnel exposure.

 

Panel-mount signal lights

Panel-mount signal lights are compact visual indicators designed for installation in machine control panels, operator stations and electrical enclosures.

They provide local indication of operating status, machine faults, control system conditions and other information relevant to the operator.

 

Surface-mount warning lights

Surface-mount warning lights are installed directly on machinery, protective enclosures, equipment housings or supporting structures.

They provide visible warnings near machine operating areas and can be positioned to suit the required viewing direction, installation arrangement and environmental conditions.

 

Multifunction LED signal lights

Multifunction LED signal lights combine several signalling capabilities within a single housing. Depending on the model, they may provide selectable colours, continuous illumination, flashing patterns or strobe functions.

These devices are suitable for machinery requiring multiple visual indications without installing separate warning lights for each condition.

 

Audible and visual warning devices

Combined audible and visual warning devices integrate LED signal lights with buzzers, sounders or other acoustic signalling components.

They are useful in large production halls, automated warehouses, material handling systems and industrial environments where visual warnings alone may not attract sufficient attention.

 

How to select the right industrial signal light

Selecting an industrial LED signal light requires consideration of its signalling function, electrical characteristics, mounting arrangement and operating environment.

1. Define the signalling function

Determine whether the signal light must indicate normal operation, machine faults, warning conditions, guard status or required operator action.

2. Select the colour and light pattern

Choose an appropriate colour and illumination mode, such as continuous, flashing, strobe or multicolour signalling. Signal meanings should remain consistent across the machinery or installation.

3. Check visibility and mounting position

Consider viewing distance, ambient lighting, potential obstructions and operator positions. The signal should be clearly recognisable from locations where personnel need to receive the information.

4. Verify electrical compatibility

Check the rated supply voltage, current consumption, connection type and control output compatibility.

Confirm that the selected signal light can be connected to the intended PLC, safety controller, relay or machine control circuit.

5. Assess environmental protection

Select an appropriate IP rating, housing material and operating temperature range for the installation.

Depending on the application, industrial signal lights with IP65 or IP67 protection may be suitable for environments exposed to dust or water.

Additional considerations may include vibration, cleaning processes, chemical exposure and mechanical impact. The selected device must be suitable for the actual operating conditions.

6. Determine whether audible signalling is required

Assess whether visual signalling alone provides sufficient warning or whether an audible signal is also needed.

The decision should consider ambient noise, viewing conditions, personnel requirements and the machine risk assessment.

 

Need advice selecting an industrial signal light?

Our specialists can help you select industrial signal lights, LED warning lights, signal towers and audible-visual signalling devices for your machinery or installation.

We provide technical guidance on signalling functions, electrical compatibility, mounting arrangements, environmental protection and integration with machine control systems.

Contact us for assistance selecting a suitable industrial signalling solution for your application.

Frequently Asked Questions

Industrial signal lights are used on automated production lines, packaging machines, conveyor systems, robotic cells, processing equipment and automated warehouses.

They indicate machine operating status, faults, warnings and other conditions requiring operator awareness.

A signal light provides one or more visual indications within a single device. A signal tower combines multiple illuminated segments, typically in different colours, to communicate several machine conditions from one mounting position.

Signal towers are commonly used where machine status must be visible across a production area.

Yes. Compatible industrial signal lights can be connected to PLCs, safety controllers, safety relays or suitable output modules.

They can display information such as emergency-stop activation, guard status, machine faults or reset requests. The light normally provides indication rather than performing a safety-related control function.

Industrial LED signal lights are available with different enclosure protection ratings, housing materials and operating temperature ranges.

For demanding environments, consider IP protection, vibration resistance, mechanical exposure and compatibility with cleaning chemicals or other substances. Always verify the manufacturer’s specifications.

Combined audible and visual signals may be appropriate where personnel could overlook a visual warning because of distance, restricted visibility or competing visual information.

The appropriate warning arrangement depends on the risk assessment, ambient noise and conditions in the operating environment.

Signal lights can provide information about guard locking, machine stop conditions or access permission when connected to a suitable control system.

However, an illuminated signal alone does not confirm that hazardous motion has stopped or hazardous energy has been controlled. Safe access must be established through the appropriate protective measures and procedures.

Industrial LED signal lights typically offer low power consumption, long operating life and compact construction.

Multicolour and multifunction devices can also communicate several machine conditions from a single housing, reducing the need for separate indicators.

Actual performance depends on the device specifications and operating environment.

Signal lights can display information about guard locking, stopped conditions or access permission when connected to a suitable control system.

However, an illuminated indicator alone does not verify that hazardous motion has ceased, stored energy has been controlled or all conditions for safe access have been met. Access must depend on the appropriate protective measures and procedures.