Safety switches ensure safe access to machines and installations and help prevent accidents during operation or maintenance.
€808,00
€808,00
€742,00
€742,00
€788,00
€788,00
€722,00
€722,00
€1.013,00
€1.013,00
€946,00
€946,00
A safety switch monitors access to a machine or installation. When a guard, door or hatch is opened, the switch sends a signal to the safety controller which safely removes power or stops the machine. This prevents injuries and ensures safe access to hazardous areas.
Employers are legally required to protect operators, maintenance staff and contractors. Safety switches prevent access to hazardous moving parts or stored energy. They are installed on access points and are designed with redundancy to achieve the required safety performance in accordance with international standards.
Non-locking switches: immediately stop the machine when the guard is opened.
Guard-locking switches: keep the guard locked until the machine has reached a safe stop.
Standards and safety levels:
EN/ISO 13849 (PLd or PLe)
EN 62061 (SIL2 or SIL3)
These standards define the required performance level or safety integrity level for machine safety components, depending on your risk assessment.
Safety switches are used on machinery and installations where moving parts or hazardous energies are present. They apply in packaging, food processing, logistics systems such as conveyors, chemical plants, and ATEX environments. They are essential for presses, robots and large mechanical systems to guarantee safe access.
Yes. Modern safety switches are available with network integration using ProfiNet, Ethernet/IP and AS-Interface. These allow easy integration with automation systems. Systems like amGard Pro Network even support PoE, integrated diagnostics and reduced wiring.
RFID safety switches provide high protection against manipulation thanks to uniquely coded actuators (EN ISO 14119). They recognise only the correct actuator, preventing bypassing. They are contactless, wear-free and easy to install, ideal for applications requiring high reliability such as pharmaceuticals, food processing and advanced machinery.
PL (Performance Level) is defined in EN/ISO 13849. PLd is suitable for medium-risk applications, while PLe is required for high-risk scenarios where severe injury or fatal accidents are possible. Our safety switches are certified for both levels and can be selected according to your risk assessment.
Our safety switches combine high safety ratings (up to PLe and SIL3) with durable construction and advanced integration options. You can choose mechanical or contactless versions, with or without guard locking. They suit sliding doors, hinged doors and hatches, and can be equipped with push buttons, emergency release, LED indication and network communication.
Machines with run-down time—such as robots, saws or hydraulic presses—must use guard-locking switches. These ensure the guard remains locked until all hazardous motion has fully stopped. Solutions like amGard Pro or tGard offer reliable protection where residual energy or delayed stopping is present.
For applications where manipulation must be prevented, RFID-coded switches are the best choice. Models such as ATOM, HGL and tGard from Fortress Safety meet EN ISO 14119 requirements and recognise only the correct actuator. They are resistant to manipulation or bypass magnets.
In situations where personnel can physically enter a machine area—such as robot cells—escape release is mandatory. Use safety switches with internal emergency release such as amGard Pro, tGard or amGard Network. Additional use of personal safety keys or Lockout-Tagout improves protection further.
For food, beverage, pharmaceutical and cleanroom applications, hygienic models such as the HGL series are recommended. They are 3-A certified, IP69K rated and resistant to chemicals, high-temperature cleaning and washdown. They meet HACCP and EHEDG requirements.
In wet, hot, cold or aggressive conditions, full stainless steel safety switches such as amGard S40 or HGL are ideal. They are IP69K rated, chemically resistant and withstand intensive cleaning, dust, dirt and vibration. This ensures reliable operation even in the harshest environments.
For gas and dust explosion hazards, ATEX 114 compliant switches are required. Our Alfred series meets requirements for zones 0–2 (gas) and 20–22 (dust). Alternatively, mechanical key-transfer systems can be used to operate access points from outside the ATEX zone.
1. Safety level: Determine the required PL or SIL using a risk assessment.
2. Run-down time: If yes, choose a guard-locking switch.
3. Entrapment risk: Use switches with escape release or safety keys.
4. Environmental factors: Consider IP rating, ATEX, hygiene or vibration.
5. Network integration: Choose models with ProfiNet, Ethernet/IP or AS-i.
Our specialists are ready to help you choose the correct safety switch. We offer technical support, custom configurations and optional on-site assessments. Contact us for expert, practical advice.
One of our sales engineers will be happy to help you in person.
Fill out the form, or call +31 (0)10 8224400
Een van onze sales engineers helpt je graag persoonlijk verder.
Vul het formulier in, of bel naar +31 (0)10 8224400